Huawei’s S5720-EI Series Gigabit Switches provide resilient, energy-efficient GE ports for access switching in data centers, and aggregation switching in enterprise campus networks. Performance enhancements include advanced processing hardware, 10 Gbit/s uplink ports, and large MAC address and routing tables; Super Virtual Fabric (SVF) support enables intelligent virtualization, iStack clustering, and operation in N + 1 backup mode for simplified O&M and high availability. Mature IPv6 features ensure smooth migration to next-generation IP networking.
The S5720-EI supports Super Virtual Fabric (SVF), which virtualizes core, aggregation and access switches, and wireless APs into one device for simplified management. SVF virtualizion also enable plug-and-play provisioning of access switches and APs; and supports profile-based service configuration and automatic delivery of configurations from core devices to aggregation and access devices.
Easy Operation provides zero-touch deployment, enabling the replacement of faulty devices without additional configuration; plus USB-based deployment, batch configuration, and batch remote upgrades — greatly reducing O&M costs. Further flexibility is provided by support for Simple Network Management Protocol (SNMP) v1, v2c, and v3; a Command Line Interface (CLI), web-based network management systems, and Secure Shell (SSH) v2.0. Support for Remote Network Monitoring (RMON), multiple log hosts, port traffic statistics collection, and comprehensive network quality analysis help in network consolidation and reorganization processes. S5720-EI models with prepositive power sockets can be installed in 12-inch (300 mm) depth cabinets, and can be maintained through the front panel for easy operation and maintenance. Cabinets can be placed against the wall or back-to-back for installation in small equipment rooms.Item | S5720-32P-EI-AC | S5720-32X-EI-AC | S5720-36PC-EI-AC | S5720-36C-EI-AC |
S5720-52P-EI-AC | S5720-32X-EI-24S-AC | S5720-56PC-EI-AC | S5720-36C-PWR-EI-AC | |
S5720-50X-EI-AC | S5720-36C-EI-28S-AC | |||
S5720-50X-EI-46S-AC | S5720-56C-EI-AC | |||
S5720-52X-EI-AC | S5720-56C-PWR-EI-AC(AC1) | |||
S5720-56C-EI-48S-AC | ||||
Fixed Ports | C series: | |||
S5720-36C-EI-AC/ S5720-36C-PWR-EI-AC: 28 x 10/100/1,000 Base-T (4 GE Combo SFP), 4 x 10 Gig SFP+ | ||||
S5720-36C-EI-28S-AC: 28 x 100/1,000 Base-X SFP (4 GE Combo), 4 x 10 Gig SFP+ | ||||
S5720-56C-EI-AC/ S5720-56C-PWR-EI-AC(AC1): 48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ | ||||
S5720-56C-EI-48S-AC: 48 x 100/1,000 Base-X SFP, 4 x 10 Gig SFP+ | ||||
PC series: | ||||
S5720-36PC-EI-AC: 28 x 10/100/1,000 Base-T (4 GE Combo SFP), 4 Gig SFP | ||||
S5720-56PC-EI-AC: 48 x 10/100/1,000 Base-T, 4 Gig SFP | ||||
X series: | ||||
S5720-32X-EI-AC: 24 x 10/100/1,000 Base-T, 4 x 100/1,000 Base-X SFP, 4 x 10 Gig SFP+ | ||||
S5720-32X-EI-24S-AC: 24 x 100/1,000 Base-X SFP, 4 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ | ||||
S5720-50X-EI-AC: 46 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ | ||||
S5720-50X-EI-46S-AC: 46 x 100/1,000 Base-X SFP, 4 x 10 Gig SFP+ | ||||
S5720-52X-EI-AC: 48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ | ||||
P series: | ||||
S5720-32P-EI-AC: 24 x 10/100/1,000 Base-T, 4 x 100/1,000 Base-X SFP, 4 Gig SFP | ||||
S5720-52P-EI-AC: 48 x 10/100/1,000 Base-T, 4 Gig SFP | ||||
Extended Slot | NA | One extended slot that supports an uplink interface card or private stack card | ||
DRAM and Flash | SDRAM: 2 GB | |||
Flash : 340 MB | ||||
MAC Address Table | IEEE 802.1d | |||
64K MAC address entries | ||||
MAC address learning and aging | ||||
Static, dynamic, and blackhole MAC address entries | ||||
Packet filtering based on source MAC addresses | ||||
VLANs | 4K VLANs | |||
Guest VLAN and voice VLAN | ||||
GVRP | ||||
MUX VLAN | ||||
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports | ||||
1:1 and N:1 VLAN mapping | ||||
VLAN-based transparent transmission of protocol packets | ||||
Jumbo Frame | 12K | |||
Ring Protection | RRPP ring topology and RRPP multi-instance | |||
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover | ||||
Smart Ethernet Protection (SEP), G.8032 Ethernet Ring Protection Switching (ERPS) | ||||
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) | ||||
BPDU protection, root protection, and loop protection | ||||
BPDU tunnel | ||||
IP Routing | Static routing, RIPv1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and policy-based routing | |||
IPv6 Features | Neighbor Discovery (ND) | |||
Path Maximum Transmission Unit (PMTU) | ||||
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet | ||||
6to4 tunnel, ISATAP tunnel, and manually configured tunnel | ||||
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types | ||||
Multicast Listener Discovery (MLD) v1/v2 snooping | ||||
Multicast Forwarding | IGMP v1/v2/v3 snooping and IGMP fast leave | |||
Multicast forwarding in a VLAN and multicast replication between VLANs | ||||
Multicast load splitting among trunk member ports | ||||
Controllable multicast | ||||
Layer 2 multicast control | ||||
Port-based multicast traffic statistics collection | ||||
IGMPv1/v2/v3, Protocol Independent Multicast Sparse Mode (PIM-SM), and Protocol Independent Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM) | ||||
Multicast Source Discovery Protocol (MSDP) | ||||
QoS/ACL | Inbound and outbound traffic rate limiting on a port | |||
Packet redirection | ||||
Broadcast storm control | ||||
Port-based traffic policing and two-rate and three-color CAR | ||||
Eight queues per port, Weighted Round Robin (WRR), Deficit Round Robin (DRR), | ||||
Strict Priority (SP), WRR + SP, and DRR + SP queue scheduling algorithms | ||||
Weighted Random Early Detection (WRED) | ||||
Re-marking of the 802.1p priority and DSCP value of packets | ||||
Packet filtering based on Layer 2 to Layer 4 information, including source MAC addresses, destination MAC addresses, source IP addresses, destination IP addresses, TCP/UCD source/destination ports, protocol types, and VLAN IDs | ||||
Per queue rate limiting and interface traffic shaping | ||||
1:1,N:1,N:4 port mirroring | ||||
VLAN mirroring | ||||
Security Features | Hierarchical user management and password protection | |||
DoS attack defense, ARP attack defense, and ICMP attack defense | ||||
Binding of the IP address, MAC address, interface number, and VLAN ID of a user | ||||
Port isolation, port security, and sticky MAC | ||||
MAC Forced Forwarding (MFF) | ||||
Blackhole MAC address entries | ||||
Limit on the number of learned MAC addresses | ||||
IEEE 802.1x authentication and the limit on the number of users on an interface | ||||
AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC | ||||
SSH v2.0 | ||||
Hypertext Transfer Protocol Secure (HTTPS) | ||||
CPU defense | ||||
Blacklist and whitelist | ||||
MACSec ready | ||||
Access Security | DHCP Relay | |||
DHCP Server | ||||
DHCP Snooping | ||||
DHCP Client | ||||
DHCP Security | ||||
Port Aggregation | LACP | |||
Up to 64 trunk groups | ||||
Up to 8 member interfaces in each trunk group | ||||
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) | |||
ITU-Y.1731 | ||||
BFD for BGP/IS-IS/OSPF/static route | ||||
Management and Maintenance | iStack | |||
Virtual cable test | ||||
SNMPv1/v2c/v3 | ||||
RMON/RMON2 | ||||
Web-based network management system | ||||
System logs and multi-level alarms | ||||
sFlow | ||||
LLDP/LLDP-MED | ||||
Secure Copy Protocol (SCP), TFTP, FTP | ||||
Store dual software images and configuration files | ||||
802.3az Energy Efficient Ethernet (EEE) | ||||
Interoperability | VLAN-based Spanning Tree (working with PVST/PVST+/RPVST) | |||
Link-type Negotiation Protocol (LNP), similar to the Dynamic Trunking Protocol (DTP) | ||||
VLAN Central Management Protocol (VCMP), similar to the VLAN Trunk Protocol (VTP) | ||||
Operating Environment | Operating temperature: | |||
Zero to 1,800m altitude: 0°C to 45°C | ||||
1,800m to 5,000m altitude: Operating temperature reduces by 1°C for every altitude increase of 220m. | ||||
Relative humidity: 5% to 95% (non-condensing) | ||||
Input Voltage | AC: | |||
Rated voltage range: 100V to 240V, 50/60 Hz | ||||
Maximum voltage range: 90V to 264V, 47/63 Hz | ||||
DC: | ||||
Rated voltage range: –48V to –60V | ||||
Maximum voltage range: –36V to –72V | ||||
Dimensions (W x D x H, in mm) | 442 x 220 x 43.6 | 442 x 420 x 43.6 | ||
Front Power Input | S5720-32P-EI-AC: Yes | S5720-52X-EI-AC: No | No | |
S5720-52P-EI-AC: No | Others: Yes | |||
Typical Power Consumption | C series: | |||
S5720-36C-EI-AC: 39.5W | ||||
S5720-36C-PWR-EI-AC: without PD: 48.5W, with PD: <864.3W (PoE: 740W) | ||||
S5720-36C-EI-28S-AC: 47.9W | ||||
S5720-56C-EI-AC: 40.5W | ||||
S5720-56C-PWR-EI-AC: without PD: 53.5W, with PD: <889.4W (PoE: 740W) | ||||
S5720-56C-PWR-EI-AC1: without PD: 53.5W, with PD: <1,564.8W (PoE: 1,440W) | ||||
S5720-56C-EI-48S-AC: 68.8W | ||||
PC series: | ||||
S5720-36PC-EI-AC: 38.3W | ||||
S5720-56PC-EI-AC: 39.3W | ||||
X series: | ||||
S5720-32X-EI-AC: 40.9W | ||||
S5720-32X-EI-24S-AC: 55.5W | ||||
S5720-50X-EI-AC : 47.5W | ||||
S5720-50X-EI-46S-AC: 73.8W | ||||
S5720-52X-EI-AC: 52.3W | ||||
P series: | ||||
S5720-32P-EI-AC: 39.8W | ||||
S5720-52P-EI-AC: 51.1W |