Новое поступление
Характеристики
*Текущая стоимость 57 782,99 уже могла изменится. Что бы узнать актуальную цену и проверить наличие товара, нажмите "Добавить в корзину"
Месяц | Минимальная цена | Макс. стоимость | Цена |
---|---|---|---|
Sep-16-2025 | 68761.38 руб. | 72199.87 руб. | 70480 руб. |
Aug-16-2025 | 68183.72 руб. | 71592.60 руб. | 69887.5 руб. |
Jul-16-2025 | 57204.1 руб. | 60064.93 руб. | 58634 руб. |
Jun-16-2025 | 67027.92 руб. | 70378.84 руб. | 68702.5 руб. |
May-16-2025 | 58360.88 руб. | 61278.46 руб. | 59819 руб. |
Apr-16-2025 | 65871.48 руб. | 69165.17 руб. | 67518 руб. |
Mar-16-2025 | 65294.35 руб. | 68559.90 руб. | 66926.5 руб. |
Feb-16-2025 | 64716.99 руб. | 67952.42 руб. | 66334 руб. |
Jan-16-2025 | 64138.55 руб. | 67345.79 руб. | 65741.5 руб. |
Описание товара
Shipping policy:Liquid and battery not included during the shipping
Multiparameter portable pH/Conductivity meter contains 6 measurement modes, the meter is suitable for measuring the pH, ORP, conductivity, TDS, salinity and resistivity.
pH Mode:
• Multiparameter portable pH/conductivity meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer group (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode diagnosis with pH slope and offset display.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes provide the reliable ORP measurements.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration, automatically recognizes the conductivity standard solutions.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Hold feature senses and locks the measurement endpoint.
• Battery indicator shows the remaining battery capacity.
• Auto-Power Off effectively conserves battery life.
• Calibration report provides the details for checking the electrode performance.
• Setup menu allows setting the 12 parameters, including the number of calibration points,
stability criteria, temperature unit, date and time, etc.
• Reset feature automatically resumes all settings back to factory default options.
• Expanded memory stores and recalls up to 500 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that use the
meter smoothly.
Model |
Bante902P |
|
pH |
||
Range |
-2.000~20.000pH |
|
Accuracy |
±0.002pH |
|
Resolution |
0.1, 0.01, 0.001pH, selectable |
|
Calibration Points |
1 to 5 points |
|
pH Buffer Options |
USA, NIST, DIN or Custom |
|
mV |
||
Range |
±1999.9mV |
|
Accuracy |
±0.2mV |
|
Resolution |
0.1, 1mV, selectable |
|
Calibration Points |
1 point |
|
Measurement Modes |
Relative or Absolute mV |
|
Conductivity |
||
Range |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
|
Accuracy |
±0.5% F.S |
|
Resolution |
0.001, 0.01, 0.1, 1 |
|
Calibration Points |
1 to 5 points |
|
Calibration Solutions |
10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm |
|
Temperature Coefficient |
0.0~10.0%/°C |
|
Compensation Modes |
Linear or Pure water |
|
Cell Constant |
K=0.1, 1, 10 or Custom |
|
Reference Temperature |
20°C or 25°C |
|
TDS |
||
Range |
0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) |
|
Accuracy |
±1% F.S |
|
Resolution |
|
0.01, 0.1, 1 |
TDS Factor |
|
0.1~1.0 (Default 0.5) |
Salinity |
||
Range |
0.00~80.00ppt, 0.00~42.00psu |
|
Accuracy |
±1% F.S |
|
Resolution |
|
0.01 |
Measurement Modes |
|
Practical salinity (psu) or Natural seawater (ppt) |
Resistivity |
||
Range |
0.00~20.00MΩ |
|
Accuracy |
±1% F.S |
|
Resolution |
0.01, 0.1, 1 |
|
Temperature |
||
Range |
0~105°C, 32~221°F |
|
Accuracy |
±0.5°C |
|
Resolution |
0.1°C, 0.1°F |
|
Calibration Points |
1 point |
|
Calibration Range |
Measured value ±10°C |
|
General |
||
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
|
Data Hold |
Manual or Auto-Endpoint |
|
Stability Criteria |
Low or High |
|
Calibration Due Alarm |
1 to 31 days or Off |
|
Power Off |
Manual or Automatic (10, 20, 30 minutes) |
|
Reset Function |
Yes |
|
Memory |
Stores up to 500 data sets |
|
Output |
USB communication interface |
|
Connector |
BNC, 6-pin mini plug |
|
Display |
LCD |
|
Power |
3×1.5V AA batteries or DC5V power adapter |
|
Battery Life |
Approximately 150 hours (Turn off the backlit) |
|
Dimensions |
170(L)×85(W)×30(H)mm |
|
Weight |
300g |
Смотрите так же другие товары: