Характеристики
Original External S Meter SWR Power For Yaesu FT-857 FT-897 Practical | Инструменты
История изменения цены
*Текущая стоимость уже могла изменится. Что бы узнать актуальную цену и проверить наличие товара, нажмите "Добавить в корзину"
Месяц |
Минимальная цена |
Макс. стоимость |
Цена |
Sep-15-2025 |
0.92 руб. |
0.36 руб. |
0 руб. |
Aug-15-2025 |
0.78 руб. |
0.9 руб. |
0 руб. |
Jul-15-2025 |
0.70 руб. |
0.34 руб. |
0 руб. |
Jun-15-2025 |
0.52 руб. |
0.45 руб. |
0 руб. |
May-15-2025 |
0.58 руб. |
0.30 руб. |
0 руб. |
Apr-15-2025 |
0.33 руб. |
0.31 руб. |
0 руб. |
Mar-15-2025 |
0.90 руб. |
0.82 руб. |
0 руб. |
Feb-15-2025 |
0.93 руб. |
0.52 руб. |
0 руб. |
Jan-15-2025 |
0.55 руб. |
0.25 руб. |
0 руб. |
Описание товара







Original External S Meter SWR Power Meter For Yaesu FT-857 FT-897 Practical
Description:
Receive Display Settings: 1, press [FUNC] key to enter the setup menu, enable the extended menu. 2, rotate [SELECT] to call up the setup menu item No-060 [MTR ARX SEL]. 3, rotate [DIAL] to select an external instrument display: SIG: the input signal strength display CTR: Discriminator Center Meter VLT: battery voltage N / A: blank FS: buckle in the instrument 1mA full scale output signal calibration standard external instruments OFF:Turn off the meter. 4, press [FUNC] button to save the settings and exit the setup menu.Emission Display Settings:1, press [FUNC] key to enter the setup menu, enable the extended menu.2, rotate [SELECT] to call up the setup menu item No-061 [MTR ATX SEL].3, rotate [DIAL] to select an external instrument display:PWR: transmit power displayALC: Automatic Level Control voltage displayMOD: Modulation Level DisplaySWR: SWR displayVLT: Display Supply VoltageN / A: blankOFF: Turn off the meter.![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Calibration method is as follows: 1, press [FUNC] key to enter the setup menu, enable the extended menu. 2, rotate [SELECT] to call up the setup menu item No-060 [MTR ARX SEL]. 3, rotate [DIAL] to select FS. 4, with a small flathead screwdriver to adjust the calibration adjustment hole rear, so the header pointer to full scale. 5, the calibration is complete!Package Included :External S Meter/SWR/Power Meter for Yaesu FT-857/FT-897 Metal Case CoverNOTE: If you can not find the numbers 60, 61 menu, is this two radio hidden menu. Long press the F key to open the menu settings, the 1st menu set to ON, press the F key to open the exit to save the hidden menu
Смотрите так же другие товары: